Add to Cart
Stainless Steel Inner CO2 Cell Culture Carbon Dioxide Incubator For Lab
HCP-160S
Scope:
●It an advanced instrument applies to cells, tissues, and bacterial culture . Is the key equipment to carry out essential immunology, oncology, genetics and bio-engineering. Widely used in microorganisms, agricultural science, drug research and production.
Feature:
●Microcomputer intelligent PID control technology, to maintain accurate and constant temperature and with timing, also with ultra-high temperature alarm function.
●Internally equipped with a UV germicidal lamp, which can effectively kill bacteria, fungi, mycoplasma and other microorganisms
●The unique air circulation, soft wind, to ensure temperature uniformity
●Gas distribution type, CO2 recovery time ≤ concentration x 1.2Min
●Adopt door heating control system,which can effectively avoid frost in glass doors.
●The design of the double doors, built-in tempered glass viewing window, clear observation of the locker, shelf up and down pitch adjustable.
Technical Parameters:
Model | Temp range (℃) | Accu racy (℃) | Fluct uation (%) | CO2 control range | Vlotage (V) | Power (KW) | Inner size (mm) (H*W*D) | Overall dimension (mm) (H*W*D) | Packing size (mm) (H*W*D) | Net weight (KG) | Shiping weight (KG) |
HCP-80S | RT +5~60 | ±0.1 | ±0.5 | 0~20% | 220 | 0.35 | 500×400×400/80L | 835×550×550 | 955×630×630 | 36 | 40 |
HCP-160S | 0.35 | 650×550×500/160L | 985×700×650 | 1105×780×730 | 57 | 62 |
CR series
ALLHEAT™Chamber Preheating Technology:
●ALLHEAT™ Chamber preheating technology is the heating element is evenly distributed in the interior pre-heating of the cavity inner wall, and then through the heat transfer and forced-fan convection, so that the temperature of each cavity can accurately reach and maintain the set value, thus ensuring uniform distribution of the cavity temperature.
●Chamber of six surface heating, in which the glass door to possession of the heating system to prevent condensation of glass doors.
●ALLHEAT™ series CO2 Incubator with low energy consumption and heat characteristics not easily lost. Save energy, enabling customers to use the cost reduction.
ALLFLOW™ Clean Air Circulation System:
●Perfect forced convection ALLFLOW™of air circulation system to ensure the shortest of temperature recovery after door. With internationally renowned brands with a cooling fan (maintenance, durability), the experimental and the training effect to the extent desired;
●ALLFLOW™ air circulation system sufficiently to ensure the continuous stability of the temperature of the working chamber. Customer set temperature is reached, given the perfect environment for sample roasting / culture;
●CO2 inlet valve with a filter device to ensure cleanliness of the cavity gas;
●Equipped with UV sterilization system in the chamber regular basis to eliminate the cavity contaminating microorganisms, effectively prevent the training during the cross-contamination.
ALLSENS™ Programmable PID Controller:
●Integrated, dot-matrix LCD display, Chinese and English subtitles, design for the highest operational comfort. Display parameters: Temp. Setting value; Temp. Measuring value, Humidity, CO2 setting value, CO2 measuring value, Heating, Fast input, Sloe input, Sterilization, run/stop.
●Adaptive PID controller precisely control the temperature and humidity, prevent temperature soaring, keep working room temperature stable and uniformity.
●User password protection, built-in multifunctional memory menu, connect to multiple devices (up to 16 units), real-time monitoring.
●Set operations with beep tips.
●Remote-controlled operation, with programmable ALLSENS™ software (option).
ALLMIST™ Inside Water Pan Humidification Technology:
●The original water pan liner integrated humidifier design, that the water quickly atomized.
●Soft air with water vapor of the water pan out the cavity humidity up and recovery, to ensure that the culture needed to saturated water.
Pro-Insulation™ Isolation Insulation Technology:
●Inner isolation gate design, take full account of customers in the observation of cavity samples, ensure the consistency of the cavity temperature.
●Based on the effective use of heat design, complete isolation between the liner and shell to avoid energy loss due to heat transfer.
●Imports high-density thermal insulation material wrapped liner, insulation well.
●Good silicone door seal, with the magnet outside the door design, ensure tightness.
Excellent Imported Sensor:
●Imported industrial sensor PT100, short response time, low self-heating temperature.
●Imported humidity sensor, aerospace material, no maintenance, precision humidity control level.
●Imported IR CO2 concentration sensor with automatic temperature compensation allows high humidity (> 98%) long-term use of the environment, high accuracy, low drift, and the CO2 concentration can be fast recovery characteristics.
Ergonomic design:
●Laboratory of classical color design, international fashion design, arc-shaped design, for highest operational comfort.
●Integrated design that contains original outside handle and LCD screen, ergonomic structure, comfortable viewing angle, convenient to open the outside door and operate interface.
●Interval and number of mesh shelf can be adjusted according to customer requirements. Maximum capacity to meet customer needs.
●Vertical cabinet classic design of structural, electrical components located in the upper cabinet to facilitate maintenance.
●Comfortable vertical structure, maximize work chamber, working room in the upper, convenient to take.
●Double door design, easy observation samples, keep temperature stability, with bell-type lighting system.
●With a test hole in the inner door, easy to test.
Modern Manufacturing Processes:
●Sheet metal parts use laser cutting and CNC bending technology. Cold-rolled sheets use three line of acidification anti-rust technology. Incubator surface use workmanship of spraying plastics.
●Inner chamber is made of SUS304 stainless steel materials.